Station FS1 (Falkland-Signy Transect - Position 1 at the North)           
===============================================================
                                                
file fs1.9092.acc:

Use (a) or (c), not (b).

From tidal analysis, data from this third deployment at FS1 appear to be
about 6 minutes too soon using semidiurnals (i.e. phase lags are about 3
degrees less) and correspondingly different values for diurnals. There may
well therefore be a systematic clock shift in this deployment.
      Posn FS13
      MK IV
      STANLEY END
      DEPLOYED 21-11-90 at 0305Z  on seabed at 0348Z
      DEPTH                   2800 m

      POSITION SAT 0250Z   53 30.7 S
                           56 58.8 W
      ACOUSTICS  2517 320, 259, 1.16
                 2518 320, 278, 1.16
          Temp
          Temp ZT4
(a)       Pressure DQ 41097
(b)       Pressure DQ 41083
(c)       Pressure DQ 41079
      1st Scan  00000 1500.00Z G.M.T. 21-11-90
      Last Scan 39779 0001.56Z   "     9-01-92

Stations in the Scotia Sea and Drake Passage
============================================

POL deployments in this area were first made in a section between the
Falkland Islands and Signy in the South Orkney islands. These stations
have names like 'FS1'. Recording then moved west to two deeper (4000 m)
stations on the western side of the Drake Passage ('ND1' and 'SD1'), and,
most recently, have been on a section between the Falklands and Elephant
Island along the official 'Drake Passage' hydrographic section for the
World Ocean Circulation Experiment ('ND2' and 'SD2' with the stations
including MYRTLE in between).

The nomenclature 'ND1' etc. follows that of

M.Meredith, 1995. On the temporal variability of the transport through
the Drake Passage. University of East Anglia Ph.D thesis. In other
publications, for example:

Woodworth, P.L., Vassie, J.M., Hughes, C.W. and Meredith, M.P. 1996.
A test of the ability of TOPEX/POSEIDON to monitor flows through
the Drake Passage. Journal of Geophysical Research, 101(C5), 11935-11947.

ND1 is referred to as DN92, SD1 as DS92, ND2 as DN93 and SD2 as DS93.

Most instruments were Paroscientific Digiquartz (DQ) pressure transducers
with temperature also recorded. BPR's had typically 3 sensors. Instrumental
drift has attempted to be removed from all records.