INFORMATION FOR BODC SERIES REF. NO.    47406                  
                                                                                
 ===============================================================================
                                                                                
                         Sea Floor Pressure Gauge Inventory Number :   7072     
                                                                                
 Start Time : 05 Oct 1982 0200 GMT                  Latitude  :  63deg 07.9min N
 End Time   : 18 Mar 1983 0100 GMT                  Longitude : 000deg 00.4min W
                                                                                
 Nominal Cycle Interval   : 3600.0 secs         Sensor Depth    :   1579.00m    
                                                Sea Floor Depth :   1579.00m    
                                                                                
 Positional Uncertainty   : 0.1 to 0.5 n.miles                                  
 Depth Datum              : Instantaneous                                       
                                                                                
 Project                  : Continental Slope Experiment (CONSLEX)              
                                                                                
 Data Category            : Offshore sea floor pressure series                  
 Instrument Type          : Tide gauge (unspecified)                            
 Instrument Mounting      : Sea floor - fixed                                   
 Originator Laboratory    : Proudman Oceanographic Laboratory, Bidston, UK      
 Originator's Identifier  : SG4DP6                                              
                                                                                
 ===============================================================================
                                                                                
 Additional information stored with the data:                                   
                                                                                
    Clock lost 1 minute 15 seconds over 178 days 19 hours 1 minute 15  seconds; 
    the original cycle interval and time values have been corrected.            
    Instrument characteristics                                                  
    Station G4                                                                  
    OSTG Mark IV No. 3   sensors  B+H4         (BODC series reference 47399)    
                                  DQ 5997      (BODC series reference 47406)    
                                                                                
    Nominal sampling interval     225 seconds                                   
    Integration period            225 seconds                                   
    Actual sampling interval      225.001092 seconds                            
                                                                                
 -------------------------------------------------------------------------------
                                                                                
 The following additional documents apply to this series:                       
                                                                                
  32414; I.O.S. Mk IV Pressure Recorder
  32428; I.O.S. Data Processing of Off-Shore Pressure Recorder Data
 Project Document        :   33549
                                              
                                                                                
 ===============================================================================